SerVision Embedded Video Gateway System Guide
Configuring Sensor and Activator Settings 117
Camera 1: Full-screen display of live video from Camera 1
Camera 2: Full-screen display of live video from Camera 2
Camera 3: Full-screen display of live video from Camera 3 (HVG, MVG, UVG only)
Camera 4: Full-screen display of live video from Camera 4(HVG, MVG, UVG only)
Rotate: Full-screen display that cycles from one camera to the next. (The rotation delay is defined in the TV-
Out Settings screen; see Configuring a CCTV Monitor (TV-Out), page 28.)
None: A digital clock is displayed, and no video is displayed.
Only one sensor connector can serve this purpose on each unit. The appropriate sensor connector for each model is:
HVG: In6 (Sensor 6)
MVG, UVG: In4 (Sensor 4)
CVG, CVG-M: In1 (Sensor 1 – the only sensor connector)
NOTE: This feature can only be activated in the relevant Sensor configuration screen if it is first enabled in
the TV-Out screen (see Configuring a CCTV Monitor (TV-Out), page 28).
NOTE: On CVG and CVG-M models, this feature should not be used if the sensor is configured to trigger
outline-switching.
To configure a sensor as a CCTV display switch:
1. In the Main Menu, under Sensors, click the appropriate sensor (see above). The Sensor configuration screen
opens.
Figure 131: Sensor #4 configuration screen (MVG, UVG)
Note: Every time the CCTV display is switched, a sensor event is triggered. If notification settings are
activated, notifications will be triggered each time the display is changed.
2. Select the TV-Out Display Switch checkbox.
3. Click Update, and then save the settings. They will be implemented after the unit is restarted (see Saving
Configuration Changes, page 125).